Skip to main content

TableĀ 3 Validity of parameters in the diagnosis of ACL functional integrity

From: Is conventional magnetic resonance imaging superior to radiography in the functional integrity evaluation of anterior cruciate ligament in patients with knee osteoarthritis?

Parameters

Cut-off value

Sensitivity (%)

Specificity (%)

Youden index (%)

Accuracy (%)

PLR

NLR

PPV (%)

NPV (%)

AUC [95% confidence interval (CI)]

P-value

HKA (°)

169.05

66.1

68.9

35.0

68.3

2.125

0.492

35.0

88.9

0.702 (0.621–0.783)

< 0.001

MPTA (°)

83.05

41.9

84.8

26.7

76.1

2.757

0.685

40.6

85.1

0.640 (0.553–0.727)

0.001

LDFA (°)

-

-

-

-

-

-

-

-

-

0.520 (0.437–0.602)

0.633

PTSPM (°)

8.80

41.9

87.3

29.2

78.1

3.299

0.666

45.6

85.5

0.667 (0.587–0.746)

< 0.001

PTSAA (°)

10.35

50.0

77.9

27.9

72.2

2.262

0.642

36.5

86.0

0.655 (0.575–0.736)

< 0.001

JLCAAPS (°)

6.45

56.5

66.8

23.3

64.7

1.702

0.651

30.2

85.8

0.656 (0.579–0.732)

< 0.001

JLCAAP (°)

3.65

61.3

57.4

18.7

58.2

1.439

0.674

26.8

85.4

0.606 (0.525–0.688)

0.010

JLCAVS (°)

-

-

-

-

-

-

-

-

-

0.533 (0.447–0.620)

0.416

STFS (mm)

1.74

35.5

84.8

20.3

74.8

2.336

0.761

37.3

83.8

0.602 (0.518–0.686)

0.013

CTFSAPS (mm)

7.48

74.2

51.6

25.8

56.2

1.533

0.500

28.0

88.7

0.631 (0.548–0.714)

0.043

CTFSAP (mm)

8.31

41.9

84.4

26.3

75.8

2.686

0.688

40.6

85.1

0.619 (0.534–0.704)

0.004

CTFSVS (mm)

-

-

-

-

-

-

-

-

-

0.564 (0.479–0.648)

0.121

MWPPT%XR (%)

63.56

74.2

81.1

55.3

79.7

3.926

0.318

50.0

92.5

0.793 (0.731–0.856)

< 0.001

MWPPT%MRI (%)

75.48

85.5

84.8

70.3

85.0

5.625

0.171

58.9

95.8

0.880 (0.823–0.937)

< 0.001

MRI grades of ACL

-

96.7

77.5

74.2

81.4

4.298

0.043

52.2

99.0

0.871 (0.829–0.914)

< 0.001