Authors (Year) | Study Design | Sample size | Dataset | Sex (% M) | Age | BMI | Implant type | Surgical Approach | Equipment Utilized | Sensor Location | Sampling Frequency | Sampling Depth |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Goossens et al. (2020) | Retrospective Cohort | 26 | Single institution | n/a | 20–82 (range) | n/a | Profemur Gladiator | n/a | Microphone: Type 378B02, Software: Simcenter Testlab | n/a | 40.96 kHz | n/a |
Retrospective Cohort | 55 | Single institution | 17 | 66.8 ± 9.8 | 24.2 ± 3.5 | Accolade II | direct anterior | Meter: LA-7500 Software: Oscope v2.1 | 1 m above ground; 2 m away from surgical table | 64 kHz | 16 bit | |
Morohashi et al. (2017) [3] | Prospective Cohort | 71 | Single institution | 16% | 65.8 (range 41–86) | 24.3 (range 17.7–38.2) | Accolade TMZF | direct lateral: 59 anterolateral:7 | Meter: LA-4440 software: LabChart | n/a | 40 kHz | n/a |
Homma et al. (2022) [7] | Observational | 29 | Single institution | 21% | 48–89 (range) | n/a | Accolade II; Taperloc Complete Microplasty; Full-hydroxyapatite porous triple tapered stem | direct anterior | Meter: LA-7500 Software: Oscope v2.1 | 1 m above ground; 2 m away from surgical table | 64 kHz | 16 bit |
Pastrav et al. (2009) [19] | Observational | 83 | Single institution | n/a | n/a | n/a | Advanced Custom-Made Implants | n/a | Meter: Pimento vibration analyzer Software: Pimento 5.2 | n/a | n/a | n/a |
Sakai et al. (2022) [15] | Observational | 12 | Single institution | 33% | 70.1 | n/a | n/a | n/a | Directional microphone | on the right and left sides of the upper- and lower-limbs of the patient 2 m from the surgical field on each side | 44.1 kHz | 16 bit |
Retrospective Cohort | 49 | Single institution | 16% | 65.7 ± 11.3 | 24.0 ± 3.69 | Taperloc Microplasty; Accolade II | direct anterior | Meter: LA-7500 Software: Oscope v2.1 | 1 m above ground; 2 m away from surgical table | 64 kHz | 16 bit | |
Sakai et al. (2021) [16] | Retrospective Cohort | 11 | Single institution | 36% | 71.6 (range 54–81) | n/a | Acetabular cup G7 | n/a | Microphone: Mic Fp-5500 | n/a | 44.1 kHz | 16 bit |
Homma et al. (2022) [7] | Observational | 62 | Single institution | 17% | 66.3 ± 9.6 | Height:156.4 ± 7.4 Weight: 58.1 ± 11.1 | Accolade II | direct anterior | Meter: LA-7500 Software: Oscope v2.1 | 1 m above ground; 2 m away from surgical table | 64 kHz | 16 bit |
Observational | 51 | Single institution | 19% | 68 ± 13 | 23.19 ± 3.39 | Accolade II | direct anterior | Meter: LA-7500 Software: Oscope, v2.1 | 1 m above ground; 2 m away from surgical table | 64 kHz | 16 bit | |
Mulier et al. (2008) [4] | Observational | 30 | Single institution | 40% | 53.9 ± 7.6 | n/a | Intraoperatively custom made prosthesis stem; Hydroxyapatite coated Pinnacle cup | n/a | Meter: Pimento vibration analyzer software: Pimento 5.2 | FRF measured directly on the prosthesis neck | n/a | n/a |
McConnell et al. (2018) [17] | Observational | 101 | Single institution | 35% | 69.9 ± 12.3 | 29 (range 26–32) | Corail femoral stem | posterior | Microphone: Auna MRS-01 Software: Amadeus Pro v2.2.2 | At the outer edge of the laminar flow canopy | 44.1 kHz | 32 bit |