Skip to main content

Table 3 Comparison of robotic-assisted (RA) vs. computer-navigated (CN) THA 90-day and 2-year implant-related outcomes

From: No difference in clinical outcomes in robotic-assisted vs. computer-navigated total hip arthroplasty

Outcome

RA (n = 4,473)

%

CN (n = 4,473)

%

Odds ratio (OR)

95% CI

P-value

Implant complications (within 90 days)

 Dislocations

25

0.56%

34

0.76%

N/A

N/A

0.979

 Revisions

0

0.00%

0

0.00%

1.00

0.00–∞

1.000

 Aseptic Loosening

11

0.25%

12

0.27%

N/A

N/A–N/A

0.992

 Fractured Prosthetic Implant

0

0.00%

0

0.00%

N/A

N/A

1.000

 PPFx

37

0.83%

26

0.58%

0.89

0.14–3.13

0.877

 SSI

14

0.31%

12

0.27%

0.87

0.05–4.80

0.896

 PJI

29

0.65%

29

0.65%

0.92

0.21–2.78

0.900

Implant complications (within 2 years)

 Dislocations

58

1.30%

53

1.18%

0.54

0.13–1.53

0.313

 Revisions

16

0.36%

19

0.42%

0.84

0.43–1.66

0.735

 Aseptic loosening

33

0.74%

34

0.76%

1.20

0.28–3.50

0.766

 Fractured prosthetic implant

0

0.00%

0

0.00%

N/A

N/A

1.000

 PPFx

54

1.21%

40

0.89%

1.61

0.54–3.93

0.337

 SSI

26

0.58%

25

0.56%

0.82

0.13–2.91

0.789

 PJI

55

1.23%

46

1.03%

1.19

0.40–2.85

0.723

  1. OR Odds ratio, CI Confidence interval, PPFx Periprosthetic fracture, SSI Surgical site infection, PJI Periprosthetic joint infection. Definitions: N/A Not Applicable. Odds ratio and confidence intervals were not calculable due to zero event rates in both groups or insufficient data for statistical analysis. < 11: Event rates less than 11 are not reported due to database privacy policies to prevent potential identification of patients